Azuri Vezuri 5 monoblok dizalica topline R290

Azuri Vezuri 5 monoblock heat pump R290

4.5 kW / Phase 1
€4.371,01
Skip to product information
Azuri Vezuri 5 monoblok dizalica topline R290

Azuri

Azuri Vezuri 5 monoblock heat pump R290

Šifra modela: AZI-CQ4.0Pd / NpG4-E

€4.371,01
Sidrena cijena: €4.371,01
Dostupnost Dostupno Za naručivanje
Energetska oznaka
Otvori oznaku (PDF) u novoj kartici
Strength
Power supply

Cijena vrijedi za jednokratno plaćanje debitnom/kreditnom karticom ili virmanom.

Platite virmanom – 2D barkod stiže u e-mailu Nakon narudžbe skenirajte barkod u aplikaciji svoje banke („Slikaj i plati”) i uplata je gotova u par sekundi.
Dostava Zagreb: 1–3 radna danaDostava Hrvatska (osim otoka): 1–7 radnih danaOtoci – na upit
Ovlaštena montaža – vlastiti montažni timovi
Niste sigurni? Pozovite ili pišite na WhatsApp
Imate pitanje o ovoj klimi? Pitajte nas na WhatsApp Radno vrijeme: pon–pet 8–16 h
Osnovne informacije
Proizvođač
Azuri
Šifra modela
AZI-CQ4.0Pd/NpG4-E
Tehnički podaci

Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.

The Azuri Vezuri V is a monoblock air-to-water heat pump with natural refrigerant R290 for heating, cooling, and domestic hot water preparation up to 80 °C. The entire refrigeration circuit is located in the outdoor unit, and the system can be connected to underfloor heating, low-temperature radiators, or fan coil units.

Azuri Vezuri V – ambience
up to 80 °C
water outlet temperature
−25 °C
heating down to the outdoor temperature
5.2
COP at A7/W35 (4.5 kW)
R290
refrigerant

Key Benefits

Water up to 80 °C
Heating and domestic hot water with an outlet temperature of 20–80 °C
R290 refrigerant
Natural gas for high energy efficiency and reduced environmental impact.
Wide operating range
Heating from −25 to +35 °C, cooling from −15 to +48 °C, domestic hot water from −25 to +45 °C outdoor temperature.
Zonal control
Zonal control for different temperature requirements.
LCD display and Wi-Fi
LCD display with built-in temperature sensors and USB interface; Wi-Fi control option.
Quiet operation
According to the catalog, low noise level up to 40 dB(A).
Azuri Vezuri V monoblock – benefit icons from the catalog
Icons from the catalog: Wi-Fi, refrigerant, heating (red) and cooling (blue) operating range, domestic hot water preparation area, water outlet temperature.

How it works and where it is used

Monoblock: refrigeration circuit, compressor, and heat exchanger in a single outdoor unit.

Monoblock heat pump operating diagram

The outdoor unit extracts heat from the outdoor air and transfers it to the water in the heating system. According to the catalog, the system is compatible with underfloor heating, low-temperature radiators, fan coil units, and surface cooling, and enables domestic hot water heating. In summer, the same unit cools water (outlet 5–25 °C) for fan coil units or surface cooling.

Technical data

All models in the series. Performance in kW; COP/EER without unit.

Design air-to-water monoblock
Refrigerant R290
Operating range – heating −25 to +35 °C
Operating range – cooling −15 to +48 °C
Domestic hot water preparation range −25 to +45 °C
Water outlet temperature – heating/domestic hot water 20–80 °C
Water outlet temperature – cooling 5–25 °C
Power supply 1 ~ / 220–240 V / 50 Hz or 3 ~ / 380–415 V / 50 Hz
Water connection ø28 mm (1 1/10")
Model Power supply Heating A7/W35 | A7/W45 COP A7/W35 | A7/W45 Cooling A35/W7 | A35/W18 EER A35/W7 | A35/W18 Power cable Fuse
AZI-CQ4.0Pd/NpG4-E 1 phase 4.5 | 4.5 5.2 | 4.10 4.5 | 4.5 3.75 | 5.65 3 x 2.5 mm² 25 A
AZI-CQ6.0Pd/NpG4-E 1 phase 6.2 | 6.1 5.0 | 3.9 6.1 | 6.2 3.2 | 5.2 3 x 2.5 mm² 25 A
AZI-CQ8.0Pd/NpG4-E 1 phase 8.4 | 8.2 5.0 | 3.9 7.5 | 8.3 3.2 | 5.2 3 x 4 mm² 25 A
AZI-CQ10Pd/NpG4-E 1 phase 10 | 10 4.75 | 3.7 8.9 | 10 3.05 | 4.8 3 x 4 mm² 25 A
AZI-CQ12Pd/NpG4-M 3 phase 12 | 12 4.95 | 3.8 11.6 | 12 3.15 | 4.6 5 x 2.5 mm² 25 A
AZI-CQ14Pd/NpG4-M 3 phase 14 | 14 4.7 | 3.7 12.8 | 14 2.95 | 4.3 5 x 2.5 mm² 25 A
AZI-CQ16Pd/NpG4-M 3 phase 15.5 | 15 4.7 | 3.75 14 | 15.5 2.85 | 4.4 5 x 2.5 mm² 25 A

Source: Deltron Azuri residential and commercial series catalog (June 2026), p. 16, technical data p. 28.

Comparison of models in the series

  • The highest COP at A7/W35 is in the smallest model (4.5 kW): 5.2.
  • Three-phase models have the same performance and COP as single-phase models, but a lower fuse rating (25 A instead of 40 A for 12–16 kW).
  • COP at A7/W45 ranges from 3.7 to 4.1.

Comparison with other series

Azuri air-to-water heat pumps from the same catalog.

Series Design Refrigerant Water outlet (heating/domestic hot water) Heating down to Performance Domestic hot water tank
Vezuri V monoblock monoblock R290 20–80 °C −25 °C 4–16 kW —
Vezuri IV monoblock monoblock R32 20–65 °C −25 °C 6–16 kW —
Vezuri IV monoblock Max monoblock R32 20–65 °C −25 °C 18–30 kW (3 phases) —
Vezuri IV split outdoor unit + hydrobox R32 20–65 °C −30 °C 6–16 kW separate
Vezuri IV All in One outdoor unit + module with tank R32 20–65 °C −30 °C 4–16 kW 190 L built-in

Values from the Deltron catalogue. Flowing water = water temperature range for heating/DHW according to the catalogue icons; cooling: 5–25 °C for all series.

Which series is right for you

Vezuri V monoblock (R290) · this series
When the highest water temperature (up to 80 °C) and natural refrigerant R290 are priorities. The entire refrigerant circuit is in the outdoor unit, and only the water connections enter the house.
Vezuri IV monoblock (R32)
For heating, cooling, and DHW up to 65 °C with underfloor heating, low-temperature radiators, or fan coil units, without refrigerant piping in the house. Also available in a three-phase version.
View the series →
Vezuri IV monoblock Max
For larger heating requirements: 18–30 kW, three-phase power supply only.
Vezuri IV split
When the hydraulic system needs to be inside the house (hydrobox on the wall), and the outdoor unit is connected with refrigerant piping. Water does not leave the building; guaranteed heating operation down to −30 °C.
View the series →
Vezuri IV All in One
When everything is wanted in a single indoor unit: a hydraulic module and a 190 L DHW tank, along with an outdoor unit.
View the series →

R290 or R32

R290 (Series V) R32 (Series IV)
Type natural refrigerant (propane) fluorinated gas
GWP < 3 675
Flowing water temperature 20–80 °C 20–65 °C
Versions monoblock monoblock, Max, split, All in One

GWP according to the Mitsubishi Electric 2026 catalogue data: R290 < 3, R32 675, R410A 2088.

What is included in the delivery

Monoblock outdoor unit. The catalogue does not list additional accessories included in the delivery; the DHW tank, buffer tank, and hydraulic accessories are selected according to the project.

Variant designations

  • 4.5 kW / 1 phase: model AZI-CQ4.0Pd/NpG4-E
  • 6.2 kW / 1 phase: model AZI-CQ6.0Pd/NpG4-E
  • 8.4 kW / 1 phase: model AZI-CQ8.0Pd/NpG4-E
  • 10 kW / 1 phase: model AZI-CQ10Pd/NpG4-E
  • 12 kW / 1 phase: model AZI-CQ12Pd/NpG4-E
  • 14 kW / 1 phase: model AZI-CQ14Pd/NpG4-E
  • 15.5 kW / 1 phase: model AZI-CQ16Pd/NpG4-E
  • 8.4 kW / 3 phases: model AZI-CQ8.0Pd/NpG4-M
  • 10 kW / 3 phases: model AZI-CQ10Pd/NpG4-M
  • 12 kW / 3 phases: model AZI-CQ12Pd/NpG4-M
  • 14 kW / 3 phases: model AZI-CQ14Pd/NpG4-M
  • 15.5 kW / 3 phases: model AZI-CQ16Pd/NpG4-M
Technical data is taken from the Deltron catalogue (importer). Source: Deltron catalogue of Azuri residential and commercial series (June 2026). Please check the availability of the individual unit before ordering.

Možda će vam se također svidjeti