Gree Versati 4 monoblok dizalica topline

Gree Versati 4 monoblock heat pump

6 kW / Phase 1
€4.007,44
Skip to product information
Gree Versati 4 monoblok dizalica topline

Gree

Gree Versati 4 monoblock heat pump

Šifra modela: GRS-CQ6.0Pd / NhG4-E

€4.007,44
Sidrena cijena: €4.007,44
Dostupnost Dostupno Za naručivanje
Energetska oznaka
Otvori oznaku (PDF) u novoj kartici
Strength
Power supply

Cijena vrijedi za jednokratno plaćanje debitnom/kreditnom karticom ili virmanom.

Platite virmanom – 2D barkod stiže u e-mailu Nakon narudžbe skenirajte barkod u aplikaciji svoje banke („Slikaj i plati”) i uplata je gotova u par sekundi.
Dostava Zagreb: 1–3 radna danaDostava Hrvatska (osim otoka): 1–7 radnih danaOtoci – na upit
Ovlaštena montaža – vlastiti montažni timovi
Niste sigurni? Pozovite ili pišite na WhatsApp
Imate pitanje o ovoj klimi? Pitajte nas na WhatsApp Radno vrijeme: pon–pet 8–16 h
Dokumenti za preuzimanje
Energetska oznaka
Preuzmi PDF
Informacijski list
Preuzmi PDF
Osnovne informacije
Proizvođač
Gree
Šifra modela
GRS-CQ6.0Pd/NhG4-E
Tehnički podaci

Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.

Gree Versati IV is an air-to-water monoblock heat pump with R32 refrigerant – a complete solution for heating, cooling and domestic hot water preparation up to 65 °C. It is available in single-phase and three-phase versions, with a heating capacity of 6–16 kW.

Gree Versati IV monoblock – environment
20–65 °C
water outlet temperature
−25 °C
heating down to outdoor temperature
6–16 kW
heating capacity A7/W35
R32
refrigerant

Key benefits

Heating, cooling and DHW
A single unit for space heating and cooling and domestic hot water preparation up to 65 °C.
Wide operating range
Heating from −25 to +35 °C, cooling from −15 to +48 °C, DHW from −25 to +45 °C outdoor temperature.
Touchscreen LCD
High-resolution display with support for 20 languages.
Wi-Fi control
Control via Wi-Fi connection.
Monoblock design
No refrigerant piping in the building – the heating system is connected with water.
Gree Versati IV monoblock – benefit icons from the catalog
Icons from the catalog: Wi-Fi, refrigerant, heating (red) and cooling (blue) operating range, DHW preparation area, water outlet temperature.

How it works and where it is used

Monoblock: refrigerant circuit, compressor and heat exchanger in a single outdoor unit.

Monoblock heat pump operating diagram

The outdoor unit extracts heat from the outdoor air and transfers it to the water in the heating system. According to the catalog, the system is compatible with underfloor heating, low-temperature radiators, fan coil units and underfloor cooling, and enables domestic hot water heating. In summer, the same unit cools water (outlet 5–25 °C) for fan coil units or underfloor cooling.

Technical data

All models in the series. Capacity in kW; COP/EER without unit.

Version air-to-water monoblock
Refrigerant R32
Operating range – heating −25 to +35 °C
Operating range – cooling −15 to +48 °C
DHW preparation range −25 to +45 °C
Water outlet temperature – heating/DHW 20–65 °C
Water outlet temperature – cooling 5–25 °C
Power supply 1 ~ / 220–240 V / 50 Hz or 3 ~ / 380–415 V / 50 Hz
Water connection 1"
Model Power supply Heating A7/W35 | A7/W45 COP A7/W35 | A7/W45 Cooling A35/W7 | A35/W18 EER A35/W7 | A35/W18 Power cable Fuse
GRS-CQ6.0Pd/NhG4-E 1 phase 6 | 6.8 5.4 | 4.1 5.7 | 6.5 3.25 | 5.1 3 x 2.5 mm² 16 A
GRS-CQ8.0Pd/NhG4-E 1 phase 8.2 | 8.3 5.32 | 4.36 7.4 | 8.3 3.7 | 5.32 3 x 4 mm² 32 A
GRS-CQ10Pd/NhG4-E 1 phase 10.2 | 10.2 5.05 | 4.08 9 | 10.2 3.4 | 5.1 3 x 4 mm² 32 A
GRS-CQ12Pd/NhG4-E 1 phase 12 | 13 4.94 | 3.77 11.1 | 12 3.1 | 4.9 3 x 6 mm² 40 A
GRS-CQ14Pd/NhG4-E 1 phase 14.2 | 14.2 4.75 | 3.7 13.3 | 13.7 2.8 | 4.57 3 x 6 mm² 40 A
GRS-CQ16Pd/NhG4-E 1 phase 15.7 | 16.2 4.55 | 3.61 13.8 | 15.5 2.71 | 4.31 3 x 6 mm² 40 A
GRS-CQ10Pd/NhG4-M 3 phase 10.2 | 10.2 4.95 | 3.92 9.1 | 10.2 3.25 | 4.79 5 x 1.5 mm² 16 A
GRS-CQ12Pd/NhG4-M 3 phase 12 | 13 4.82 | 3.77 11.1 | 12 3.1 | 4.6 5 x 2.5 mm² 16 A
GRS-CQ14Pd/NhG4-M 3 phase 14.2 | 14.2 4.6 | 3.7 13.3 | 13.9 2.8 | 4.19 5 x 2.5 mm² 16 A
GRS-CQ16Pd/NhG4-M 3 phase 15.7 | 16.2 4.4 | 3.61 13.8 | 15.4 2.71 | 3.8 5 x 2.5 mm² 16 A

Source: Deltron catalog Gree heat pumps 2026, p. 4, installation data p. 10–11.

Comparison of models in the series

  • The 6 kW model has the highest COP at A7/W35 (5.4), and the 8 kW model at A7/W45 (4.36).
  • Three-phase models (10–16 kW) have a 16 A fuse and 5 x 1.5–2.5 mm² cable, single-phase 12–16 kW 40 A and 3 x 6 mm².

Comparison with other series

Gree air-to-water heat pumps from the same catalog.

Series Version Refrigerant Water outlet (heating/DHW) Heating down to Capacity DHW tank
Versati V monoblock monoblock R290 40–80 °C −25 °C 4–16 kW —
Versati IV monoblock monoblock R32 20–65 °C −25 °C 6–16 kW —
Versati IV monoblock Max monoblock R32 20–65 °C −25 °C 18–30 kW (3 phase) —
Versati IV split outdoor unit + hydrobox R32 20–65 °C −30 °C 6–16 kW separate
Versati IV All in One outdoor unit + module with tank R32 20–65 °C −30 °C 4–16 kW 190 L built-in

Values from the Deltron catalogue. Outlet water = water temperature range for heating/DHW according to the catalogue icons; cooling: 5–25 °C for all series.

Which series is right for you

Versati V monoblock (R290)
When the highest water temperature (up to 80 °C) and natural refrigerant R290 are priorities. The entire refrigeration circuit is in the outdoor unit, with only water connections entering the house.
View the series →
Versati IV monoblock (R32) · this series
For heating, cooling and DHW up to 65 °C with underfloor heating, low-temperature radiators or fan coil units, without cooling water in the house. Also available in a three-phase version.
Versati IV monoblock Max
For larger heating requirements: 18–30 kW, three-phase power supply only.
View the series →
Versati IV split
When the hydraulics need to be in the house (hydrobox on the wall), and the outdoor unit is connected with cooling water. Water does not leave the building; guaranteed heating operation down to −30 °C.
View the series →
Versati IV All in One
When everything is wanted in a single indoor unit: a hydraulic module and a 190 L DHW tank, along with an outdoor unit.
View the series →

R290 or R32

R290 (Series V) R32 (Series IV)
Type natural refrigerant (propane) fluorinated gas
GWP < 3 675
Outlet water temperature 40–80 °C 20–65 °C
Versions monoblock monoblock, Max, split, All in One

GWP according to the Mitsubishi Electric 2026 catalogue data: R290 < 3, R32 675, R410A 2088.

What is included in the delivery

Monoblock outdoor unit. The catalogue does not state additional accessories included in the delivery; the DHW tank, buffer tank and hydraulic accessories are selected according to the project.

Variant designations

  • 6 kW / 1 phase: model GRS-CQ6.0Pd/NhG4-E
  • 8.2 kW / 1 phase: model GRS-CQ8.0Pd/NhG4-E
  • 10.2 kW / 1 phase: model GRS-CQ10Pd/NhG4-E
  • 12 kW / 1 phase: model GRS-CQ12Pd/NhG4-E
  • 14.2 kW / 1 phase: model GRS-CQ14Pd/NhG4-E
  • 15.7 kW / 1 phase: model GRS-CQ16Pd/NhG4-E
  • 10.2 kW / 3 phases: model GRS-CQ10Pd/NhG4-M
  • 12 kW / 3 phases: model GRS-CQ12Pd/NhG4-M
  • 14.2 kW / 3 phases: model GRS-CQ14Pd/NhG4-M
  • 15.7 kW / 3 phases: model GRS-CQ16Pd/NhG4-M
Technical data taken from the Deltron catalogue (importer). Source: Deltron catalogue Gree heat pumps 2026. Please check the availability of the individual unit before ordering.