Azuri
Azuri Azuti cassette set 5 kW
Šifra modela: AUD50T1 / A1-S / ZUD50W1 / NhA-S
Montažu ovog uređaja dogovaramo na upit, prema mjestu ugradnje. Javite nam se za ponudu.
Ukupno:
Dokumenti za preuzimanje
- Energetska oznaka
- Preuzmi PDF
- Informacijski list
- Preuzmi PDF
Osnovne informacije
- Proizvođač
- Azuri
- Nazivna snaga
- 5,3 kW
- Šifra modela
- AUD50T1/A1-S / ZUD50W1/NhA-S
Tehnički podaci
| Općenito | |
|---|---|
| Tip unutarnje jedinice | Kazetna |
| Brand | Azuri |
| Model unutarnje jedinice | AUD50T1/A1-S |
| Model vanjske jedinice | ZUD50W1/NhA-S |
| Radna tvar | R32 |
| Učinak i učinkovitost | |
| Kapacitet hlađenja (kW) | 5,0 |
| Kapacitet grijanja (kW) | 5,6 |
| Energetska klasa (hlađenje) | A++ |
| Energetska klasa (grijanje) | A+ |
| SEER | 6,6 |
| SCOP | 4,0 |
| Područje rada grijanje (°C) | od −20 do +24 |
| Buka | |
| Zvučni tlak unutarnje jedinice (dB(A)) | 35–43 |
| Zvučni tlak vanjske jedinice (dB(A)) | 52 |
| Dimenzije i masa | |
| Dimenzije unutarnje jedinice V × Š × D (mm) | 260 × 570 × 570 |
| Težina unutarnje jedinice (kg) | 16,5 |
| Dimenzije vanjske jedinice V × Š × D (mm) | 555 × 745 × 300 |
| Težina vanjske jedinice (kg) | 30,5 |
| Instalacija | |
| Promjer cijevi tekuća / plinska faza (mm) | 6,35 / 12,70 |
| Max. duljina cjevovoda (m) | 30 |
| Max. visinska razlika (m) | 20 |
| Napajanje | 1-fazno, 230 V |
Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.
The Azuri Azuti cassette set (super inverter) is installed in a dropped ceiling and distributes air in four directions – for offices, shops and hospitality spaces.
Why Azuri Azuti cassette

Different louver positions enable comfortable cooling and heating without drafts, while reduced fan noise maintains a working atmosphere. The standard condensate pump has a delivery height of up to 1000 mm.

Azuti is a mono split system in which the outdoor unit connects to different types of indoor units. The dual ambient sensor precisely regulates the temperature, while the sine DC inverter compressor ensures stable cooling and heating down to −20 °C.

Low starting current and an integrated PCB board for easier maintenance make Azuti a reliable choice for offices, shops, hotels and restaurants.
Key features
Description and technical data
Azuri Azuti cassette set (super inverter) – commercial set of cassette indoor unit with mask and outdoor unit for commercial spaces.
The price is the price of the complete set (indoor + outdoor unit).
Features:
- Indoor cassette unit with standard condensate pump (delivery height up to 1000 mm)
- Reduced fan noise during operation
- Different louver positions for better comfort during cooling and heating
- Wireless remote control included
- Mono-split system: outdoor unit connects to different types of indoor units
- Dual ambient sensor for precise temperature regulation
- Low starting current
- Sine DC inverter compressor
- Integrated PCB board for easier maintenance
- Stable heating and cooling down to -20 °C outdoor temperature
- Refrigerant: R32
- Cooling operating range (outdoor temperature): -20 to +52 °C
- Heating operating range (outdoor temperature): -20 to +24 °C
- Indoor units require their own power supply 3 x 1.0 mm²; interconnection of outdoor and indoor units 2 x 0.75 mm²
Variant designations:
- 3.5 kW: indoor AUD35T1/A-S + mask TF05-A + outdoor ZUD35W1/NhA-S; nominal cooling 3.5 kW, heating 4 kW; outdoor unit power supply 1 phase (220–240 V); outdoor dimensions H/W/D 553 x 675 x 285 mm; max. pipe length / height difference 30 / 15 m; mask 620 x 620 x 47.5 mm
- 5.3 kW: indoor AUD50T1/A1-S + mask TF05-A + outdoor ZUD50W1/NhA-S; nominal cooling 5 kW, heating 5.6 kW; outdoor unit power supply 1 phase (220–240 V); outdoor dimensions H/W/D 555 x 745 x 300 mm; max. pipe length / height difference 35 / 20 m; mask 620 x 620 x 47.5 mm; indoor unit nominal 5.0 kW, outdoor 5.3 kW
- 7 kW: indoor AUD71T2/A-S + mask TF06-A + outdoor ZUD71W1/NhA-S; nominal cooling 7.1 kW, heating 8 kW; outdoor unit power supply 1 phase (220–240 V); outdoor dimensions H/W/D 660 x 889 x 340 mm; max. pipe length / height difference 50 / 25 m; mask 950 x 950 x 52 mm
- 10 kW: indoor AUD100T2/A-S + mask TF06-A + outdoor ZUD100W1/NhA-S; nominal cooling 10.5 kW, heating 11.5 kW; outdoor unit power supply 1 phase (220–240 V); outdoor dimensions H/W/D 820 x 940 x 370 mm; max. pipe length / height difference 65 / 30 m; mask 950 x 950 x 52 mm
- 12.1 kW: indoor AUD125T2/A-S + mask TF06-A + outdoor ZUD125W1/NhA-S; nominal cooling 12.1 kW, heating 13.5 kW; outdoor unit power supply 1 phase (220–240 V); outdoor dimensions H/W/D 820 x 940 x 370 mm; max. pipe length / height difference 75 / 30 m; mask 950 x 950 x 52 mm
- 13.4 kW: indoor AUD140T2/A-S + mask TF06-A + outdoor ZUD140W1/NhA-S; nominal cooling 13.4 kW, heating 15.5 kW; outdoor unit power supply 1 phase (220–240 V); outdoor dimensions H/W/D 820 x 940 x 370 mm; mask 950 x 950 x 52 mm
Technical data taken from the Deltron catalog (importer).