Gree
Gree U-Match duct kit 12.1 kW
Šifra modela: GUD125PHS1 / A-S / GUD125W1 / NhA-S
Snaga hlađenja · odaberite model
Montažu ovog uređaja dogovaramo na upit, prema mjestu ugradnje. Javite nam se za ponudu.
Ukupno:
Osnovne informacije
- Proizvođač
- Gree
- Nazivna snaga
- 12,1 kW
- Šifra modela
- GUD125PHS1/A-S / GUD125W1/NhA-S
Tehnički podaci
| Općenito | |
|---|---|
| Tip unutarnje jedinice | Kanalna |
| Brand | Gree |
| Model unutarnje jedinice | GUD125PHS1/A-S |
| Model vanjske jedinice | GUD125W1/NhA-S |
| Radna tvar | R32 |
| Učinak i učinkovitost | |
| Kapacitet hlađenja (kW) | 12,1 (3,6–13,1) |
| Kapacitet grijanja (kW) | 13,5 (3,6–14,5) |
| Energetska klasa (hlađenje) | A++ |
| Energetska klasa (grijanje) | A+ |
| SEER | 6,1 |
| SCOP | 4,1 |
| Područje rada hlađenje (°C) | od −20 do +52 |
| Područje rada grijanje (°C) | od −20 do +24 |
| Buka | |
| Zvučni tlak unutarnje jedinice (dB(A)) | 40–43 |
| Zvučni tlak vanjske jedinice (dB(A)) | 58 |
| Zvučna snaga unutarnje jedinice (dB(A)) | 66 |
| Zvučna snaga vanjske jedinice (dB(A)) | 73 |
| Dimenzije i masa | |
| Dimenzije unutarnje jedinice V × Š × D (mm) | 260 × 1340 × 655 |
| Težina unutarnje jedinice (kg) | 43,0 |
| Dimenzije vanjske jedinice V × Š × D (mm) | 820 × 940 × 370 |
| Težina vanjske jedinice (kg) | 66,0 |
| Instalacija | |
| Promjer cijevi tekuća / plinska faza (mm) | 9,52 / 15,88 |
| Max. duljina cjevovoda (m) | 75 |
| Max. visinska razlika (m) | 30 |
| Napajanje | 1-fazno, 230 V |
Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.
The Gree U-Match duct system conceals the indoor unit in a dropped ceiling – only the air grilles remain visible. Super inverter with R32, for shops, offices, hotels and restaurants.
Why the Gree U-Match duct

Compact low-profile duct units are installed in a dropped ceiling. Fresh air supply and flexible air outlets and condensate drainage make it easy to adapt to any space, while the improved air duct reduces noise.

U-Match is a mono split system in which the same outdoor unit connects to cassette, duct or floor-ceiling indoor units. The dual temperature sensor and sinusoidal DC inverter compressor ensure precise control and reliable cooling and heating down to −20 °C.
Key features
Description and technical data
Gree U-Match duct system – commercial set of duct indoor and outdoor units (super inverter, R32) for shops, offices, hotels and restaurants.
The price is the price of the complete set (indoor + outdoor unit).
Features:
- Compact low-profile units for installation in dropped ceilings
- Option to supply 8–15 % fresh air
- Flexible installation: rear or bottom air return
- Condensate pump with 1000 mm supply height (option)
- DC fan motor
- Adjustable external static pressure levels
- I-DEMAND energy saving
- Wired controller XE7A-24/H included (for 16 kW XK117); Wi-Fi controller XE7A-24/HC – option
- Super inverter, R32 refrigerant
- Reliable cooling and heating down to -20 °C outdoor temperature
- Dual temperature sensor, I-Feel function
- Fast cooling/heating function
- Intelligent defrost, automatic mode, dehumidification mode
- Option of central control (CE52-24/F(C)) and MODBUS interface (ME50-00/EG(M))
Variant designations:
- 3.5 kW: indoor GUD35PS1/A-S + outdoor GUD35W1/NhA-S – cooling/heating 3.5 / 4.0 kW, SEER/SCOP 6.5 / 4.0, A++ / A+, indoor noise 30–35 dB(A), outdoor 48 dB(A), ESP 25 Pa (0–80), max. length / height difference 30 / 15 m, 1-phase power supply (220–240 V)
- 5.3 kW: indoor GUD50PS1/A-S + outdoor GUD50W1/NhA-S – cooling/heating 5.3 / 5.6 kW, SEER/SCOP 6.3 / 4.0, A++ / A+, indoor noise 31–36 dB(A), outdoor 52 dB(A), ESP 25 Pa (0–80), max. length / height difference 30 / 20 m, 1-phase power supply (220–240 V)
- 7.1 kW: indoor GUD71PHS1/A-S + outdoor GUD71W1/NhA-S – cooling/heating 7.1 / 8.0 kW, SEER/SCOP 6.6 / 4.1, A++ / A+, indoor noise 31–37 dB(A), outdoor 55 dB(A), ESP 25 Pa (0–160), max. length / height difference 30 / 20 m, 1-phase power supply (220–240 V)
- 10.5 kW: indoor GUD100PHS1/A-S + outdoor GUD100W1/NhA-S – cooling/heating 10.5 / 11.5 kW, SEER/SCOP 6.4 / 4.2, A++ / A+, indoor noise 36–39 dB(A), outdoor 57 dB(A), ESP 37 Pa (0–160), max. length / height difference 75 / 30 m, 1-phase power supply (220–240 V)
- 12.1 kW: indoor GUD125PHS1/A-S + outdoor GUD125W1/NhA-S – cooling/heating 12.1 / 13.5 kW, SEER/SCOP 6.1 / 4.1, A++ / A+, indoor noise 40–43 dB(A), outdoor 58 dB(A), ESP 50 Pa (0–160), max. length / height difference 75 / 30 m, 1-phase power supply (220–240 V)
- 13.4 kW: indoor GUD140PHS1/A-S + outdoor GUD140W1/NhA-S – cooling/heating 13.4 / 15.5 kW, SEER/SCOP 6.1 / 4.0, A++ / A+, indoor noise 38–43 dB(A), outdoor 59 dB(A), ESP 50 Pa (0–200), max. length / height difference 75 / 30 m, 1-phase power supply (220–240 V)
- 16 kW: indoor GUD160PHS1/A-S + outdoor GUD160W1/NhA-X – cooling/heating 16.0 / 18.2 kW, SEER/SCOP 6.1 / 4.0, A++ / A+, indoor noise 38–44 dB(A), outdoor 57 dB(A), ESP 50 Pa (0–200), max. length / height difference 75 / 30 m, 3-phase power supply (380–415 V)
Technical data taken from the Deltron catalog (importer).