Azuri Vezuri 4 monoblok dizalica topline

Azuri Vezuri 4 monoblock heat pump

6 kW / Phase 1
€3.726,91
Skip to product information
Azuri Vezuri 4 monoblok dizalica topline

Azuri

Azuri Vezuri 4 monoblock heat pump

Šifra modela: AZI-CQ6.0Pd / NhG4-E

€3.726,91
Sidrena cijena: €3.726,91
Dostupnost Dostupno Za naručivanje
Energetska oznaka
Otvori oznaku (PDF) u novoj kartici
Strength
Power supply

Cijena vrijedi za jednokratno plaćanje debitnom/kreditnom karticom ili virmanom.

Platite virmanom – 2D barkod stiže u e-mailu Nakon narudžbe skenirajte barkod u aplikaciji svoje banke („Slikaj i plati”) i uplata je gotova u par sekundi.
Dostava Zagreb: 1–3 radna danaDostava Hrvatska (osim otoka): 1–7 radnih danaOtoci – na upit
Ovlaštena montaža – vlastiti montažni timovi
Niste sigurni? Pozovite ili pišite na WhatsApp
Imate pitanje o ovoj klimi? Pitajte nas na WhatsApp Radno vrijeme: pon–pet 8–16 h
Dokumenti za preuzimanje
Energetska oznaka
Preuzmi PDF
Informacijski list
Preuzmi PDF
Osnovne informacije
Proizvođač
Azuri
Šifra modela
AZI-CQ6.0Pd/NhG4-E
Tehnički podaci

Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.

Azuri Vezuri IV is an air-to-water monoblock heat pump with R32 refrigerant – a complete solution for heating, cooling and domestic hot water preparation up to 65 °C. The product includes standard 6–16 kW models and the Max 18–30 kW version.

Azuri Vezuri IV monoblock – interior
20–65 °C
water outlet temperature
−25 °C
heating down to the outdoor temperature
6–30 kW
heating capacity A7/W35
R32
refrigerant

Key Benefits

Heating, cooling and DHW
A single unit for space heating and cooling and domestic hot water preparation up to 65 °C.
Wide operating range
Heating from −25 to +35 °C, cooling from −15 to +48 °C, DHW from −25 to +45 °C outdoor temperature.
Touchscreen LCD
High-resolution display with support for 20 languages.
Wi-Fi control
Control via Wi-Fi connection.
Monoblock design
No refrigerant piping in the building – connects to the heating system with water.
Max version
18–30 kW, 380–415 V three-phase power supply; ø28 mm (18–22 kW) or ø34.9 mm (26–30 kW) water connection.
Azuri Vezuri IV monoblock – benefit icons from the catalog
Icons from the catalog: Wi-Fi, refrigerant, heating (red) and cooling (blue) operating range, DHW preparation range, water outlet temperature.

How it works and where it is used

Monoblock: refrigerant circuit, compressor and heat exchanger in a single outdoor unit.

Monoblock heat pump operating diagram

The outdoor unit extracts heat from the outdoor air and transfers it to the water in the heating system. According to the catalog, the system is compatible with surface heating, low-temperature radiators, fan coil units and surface cooling, and also enables domestic hot water heating. In summer, the same unit cools water (5–25 °C outlet) for fan coil units or surface cooling.

Technical data

All models in the series. Capacity in kW; COP/EER without unit.

Version air-to-water monoblock
Refrigerant R32
Operating range – heating −25 to +35 °C
Operating range – cooling −15 to +48 °C
DHW preparation range −25 to +45 °C
Water outlet temperature – heating/DHW 20–65 °C
Water outlet temperature – cooling 5–25 °C
Power supply 1 ~ / 220–240 V / 50 Hz or 3 ~ / 380–415 V / 50 Hz
Water connection 1" (6–16 kW) · ø28 mm (18, 22 kW) · ø34.9 mm (26, 30 kW)
Model Power supply Heating A7/W35 | A7/W45 COP A7/W35 | A7/W45 Cooling A35/W7 | A35/W18 EER A35/W7 | A35/W18 Power cable Fuse
AZI-CQ6.0Pd/NhG4-E 1 phase 6 | 6.8 5.4 | 4.1 5.7 | 6.5 3.25 | 5.1 3 x 2.5 mm² 16 A
AZI-CQ8.0Pd/NhG4-E 1 phase 8.2 | 8.3 5.32 | 4.36 7.4 | 8.3 3.7 | 5.32 3 x 4 mm² 32 A
AZI-CQ10Pd/NhG4-E 1 phase 10.2 | 10.2 5.05 | 4.08 9 | 10.2 3.4 | 5.1 3 x 4 mm² 32 A
AZI-CQ12Pd/NhG4-E 1 phase 12 | 13 4.94 | 3.77 11.1 | 12 3.1 | 4.9 3 x 6 mm² 40 A
AZI-CQ14Pd/NhG4-E 1 phase 14.2 | 14.2 4.75 | 3.7 13.3 | 13.7 2.8 | 4.57 3 x 6 mm² 40 A
AZI-CQ16Pd/NhG4-E 1 phase 15.7 | 16.2 4.55 | 3.61 13.8 | 15.5 2.71 | 4.31 3 x 6 mm² 40 A
AZI-CQ10Pd/NhG4-M 3 phase 10.2 | 10.2 4.95 | 3.92 9.1 | 10.2 3.25 | 4.79 5 x 1.5 mm² 16 A
AZI-CQ12Pd/NhG4-M 3 phase 12 | 13 4.82 | 3.77 11.1 | 12 3.1 | 4.6 5 x 2.5 mm² 16 A
AZI-CQ14Pd/NhG4-M 3 phase 14.2 | 14.2 4.6 | 3.7 13.3 | 13.9 2.8 | 4.19 5 x 2.5 mm² 16 A
AZI-CQ16Pd/NhG4-M 3 phase 15.7 | 16.2 4.4 | 3.61 13.8 | 15.4 2.71 | 3.8 5 x 2.5 mm² 16 A
AZI-CQ18Pd/NhA-M 3 phase 18 | 18 4.8 | 3.6 17.5 | 18.5 3.1 | 4.8 5 x 4 mm² 25 A
AZI-CQ22Pd/NhA-M 3 phase 22 | 22 4.5 | 3.5 21 | 23 3.0 | 4.7 5 x 4 mm² 25 A
AZI-CQ26Pd/NhA-M 3 phase 26 | 26 4.35 | 3.4 26 | 27 2.8 | 4.4 5 x 6 mm² 32 A
AZI-CQ30Pd/NhA-M 3 phase 30 | 30 4.35 | 3.4 30 | 31 2.6 | 4.1 5 x 6 mm² 32 A

Source: Deltron Azuri residential and commercial series catalog (July 2026), pages 17 and 18, technical data on page 28.

Comparison of models in the series

  • Standard 6–16 kW models (1 or 3 phase) and Max 18–30 kW version (3 phase).
  • The 6 kW model has the highest COP at A7/W35 (5.4).

Comparison with other series

Azuri air-to-water heat pumps from the same catalog.

Series Version Refrigerant Flowing water (heating/DHW) Heating up to Capacity DHW tank
Vezuri V monobloc monobloc R290 20–80 °C −25 °C 4–16 kW —
Vezuri IV monobloc monobloc R32 20–65 °C −25 °C 6–16 kW —
Vezuri IV monobloc Max monobloc R32 20–65 °C −25 °C 18–30 kW (3-phase) —
Vezuri IV split outdoor + hydrobox R32 20–65 °C −30 °C 6–16 kW split
Vezuri IV All in One outdoor + module with tank R32 20–65 °C −30 °C 4–16 kW 190 L built-in

Values from the Deltron catalogue. Flowing water = water temperature range for heating/DHW according to the catalogue icons; cooling: 5–25 °C for all series.

Which series is right for you

Vezuri V monobloc (R290)
When the highest water temperature (up to 80 °C) and natural refrigerant R290 are priorities. The entire refrigerant circuit is in the outdoor unit, and only water connections enter the house.
View the series →
Vezuri IV monobloc (R32) · this series
For heating, cooling, and DHW up to 65 °C with underfloor heating, low-temperature radiators, or fan coil units, without refrigerant piping in the house. Also available in a three-phase version.
Vezuri IV monobloc Max
For higher heating requirements: 18–30 kW, three-phase power supply only.
Vezuri IV split
When the hydraulic system needs to be in the house (hydrobox on the wall), and the outdoor unit is connected with refrigerant piping. Water does not leave the building; guaranteed heating operation down to −30 °C.
View the series →
Vezuri IV All in One
When everything is wanted in a single indoor enclosure: a hydraulic module and a 190 L DHW tank, along with an outdoor unit.
View the series →

R290 or R32

R290 (Series V) R32 (Series IV)
Type natural refrigerant (propane) fluorinated gas
GWP < 3 675
Flowing water temperature 20–80 °C 20–65 °C
Versions monobloc monobloc, Max, split, All in One

GWP according to the Mitsubishi Electric 2026 catalogue data: R290 < 3, R32 675, R410A 2088.

What is included in the delivery

Monobloc outdoor unit. The catalogue does not list additional accessories included in the delivery; the DHW tank, intercooler, and hydraulic accessories are selected according to the project.

Variant designations

  • 6 kW / 1 phase: model AZI-CQ6.0Pd/NhG4-E
  • 8.2 kW / 1 phase: model AZI-CQ8.0Pd/NhG4-E
  • 10.2 kW / 1 phase: model AZI-CQ10Pd/NhG4-E
  • 12 kW / 1 phase: model AZI-CQ12Pd/NhG4-E
  • 14.2 kW / 1 phase: model AZI-CQ14Pd/NhG4-E
  • 15.7 kW / 1 phase: model AZI-CQ16Pd/NhG4-E
  • 10.2 kW / 3 phases: model AZI-CQ10Pd/NhG4-M
  • 12 kW / 3 phases: model AZI-CQ12Pd/NhG4-M
  • 14.2 kW / 3 phases: model AZI-CQ14Pd/NhG4-M
  • 15.7 kW / 3 phases: model AZI-CQ16Pd/NhG4-M
  • 18 kW / 3 phases: model AZI-CQ18Pd/NhA-M
  • 22 kW / 3 phases: model AZI-CQ22Pd/NhA-M
  • 26 kW / 3 phases: model AZI-CQ26Pd/NhA-M
  • 30 kW / 3 phases: model AZI-CQ30Pd/NhA-M
Technical data is taken from the Deltron catalogue (importer). Source: Deltron catalogue of Azuri residential and commercial series (June 2026). Please check the availability of the individual unit before ordering.