Azuri Vezuri 4 split dizalica topline (komplet)

Azuri Vezuri 4-way heat pump splitter (kit)

6 kW / Phase 1
€4.956,91
Skip to product information
Azuri Vezuri 4 split dizalica topline (komplet)
1/3

Azuri

Azuri Vezuri 4-way heat pump splitter (kit)

Šifra modela: AZI-CQ6.0Pd / NhH3-E(I) / AZI-CQ6.0Pd / NhH3-E(O)

€4.956,91
Sidrena cijena: €4.956,91
Dostupnost Dostupno Za naručivanje
Energetska oznaka
Otvori oznaku (PDF) u novoj kartici
Strength
Power supply

Cijena vrijedi za jednokratno plaćanje debitnom/kreditnom karticom ili virmanom.

Platite virmanom – 2D barkod stiže u e-mailu Nakon narudžbe skenirajte barkod u aplikaciji svoje banke („Slikaj i plati”) i uplata je gotova u par sekundi.
Dostava Zagreb: 1–3 radna danaDostava Hrvatska (osim otoka): 1–7 radnih danaOtoci – na upit
Ovlaštena montaža – vlastiti montažni timovi
Niste sigurni? Pozovite ili pišite na WhatsApp
Imate pitanje o ovoj klimi? Pitajte nas na WhatsApp Radno vrijeme: pon–pet 8–16 h
Osnovne informacije
Proizvođač
Azuri
Šifra modela
AZI-CQ6.0Pd/NhH3-E(I) / AZI-CQ6.0Pd/NhH3-E(O)
Tehnički podaci
Tehnički podaci – 6 kW / Phase 1
Općenito
BrandAzuri
Model unutarnje jediniceAZI-CQ6.0Pd/NhH3-E(I)
Model vanjske jediniceAZI-CQ6.0Pd/NhH3-E(O)
Radna tvarR32
Učinak i učinkovitost
Nazivni učin grijanja (kW)6,2
Područje rada grijanje (°C)od −30 do +35
Instalacija
Napajanje1-fazno, 230 V

Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.

The Azuri Vezuri IV split version consists of an outdoor unit and an indoor unit (hydrobox). It provides space heating and cooling, as well as domestic hot water preparation up to 65 °C, with guaranteed heating operation at outdoor temperatures down to −30 °C.

Azuri Vezuri IV split – ambience
−30 °C
heating down to outdoor temperature
20–65 °C
water outlet temperature
hydrobox
indoor unit
R32
refrigerant

Key benefits

Heating down to −30 °C
Heating operating range from −30 to +35 °C, DHW from −30 to +45 °C, cooling from −15 to +48 °C.
Hydraulics inside the building
The outdoor unit is connected to the hydrobox via refrigerant piping; the water circuit remains inside the building.
Touchscreen LCD
High-resolution display with support for 20 languages.
Wi-Fi control
Control via Wi-Fi connection.
Pre-filled up to 10 m
Refrigerant piping pre-filled for 10 m; max. length 20 m (4.6 kW) or 30 m (8–16 kW), height difference 15 m.
Azuri Vezuri IV split – benefit icons from the catalogue
Icons from the catalogue: Wi-Fi, R32, heating/cooling operating range, DHW preparation range, water outlet temperature.

How it works and where it is used

The outdoor unit and indoor unit are connected via refrigerant piping.

Operating diagram

The outdoor unit absorbs heat from the air and transfers it to the indoor unit via refrigerant piping, where it is transferred to the water in the heating or cooling system. The heating/cooling circuits and, if required, the DHW tank are connected to the hydrobox. The system is compatible with underfloor heating, low-temperature radiators, fan coil units and underfloor cooling.

Technical data

All models in the series. Performance in kW; COP/EER without unit.

Version split: outdoor unit + hydrobox
Refrigerant R32
Operating range – heating −30 to +35 °C
Operating range – cooling −15 to +48 °C
DHW preparation range −30 to +45 °C
Water outlet temperature heating/DHW 20–65 °C, cooling 5–25 °C
Interconnection between outdoor and indoor units PPOO 5 x 1.5 mm²
Pre-filled pipe length 10 m; gas top-up 50 g/m
Max. pipe length / height difference 5–20 m / 15 m (4.6 kW) · 5–30 m / 15 m (8–16 kW)
Outdoor / indoor unit Power supply Heating A7/W35 | A7/W45 COP A7/W35 | A7/W45 Cooling A35/W7 | A35/W18 EER A35/W7 | A35/W18
AZI-CQ6.0Pd/NhH3-E(O)
AZI-CQ6.0Pd/NhH3-E(I)
1 phase 6.2 | 6 5.25 | 4.00 6.2 | 6.5 3.35 | 5.4
AZI-CQ8.0Pd/NhH3-E(O)
AZI-CQ8.0Pd/NhH3-E(I)
1 phase 8.3 | 8.2 5.30 | 3.95 7.3 | 8.4 3.40 | 5.20
AZI-CQ10Pd/NhH3-E(O)
AZI-CQ10Pd/NhH3-E(I)
1 phase 10.2 | 10 5.0 | 3.9 8.7 | 10.2 3.2 | 4.95
AZI-CQ12Pd/NhH3-E(O)
AZI-CQ12Pd/NhH3-E(I)
1 phase 11.7 | 12.5 4.91 | 3.84 11.1 | 12.2 2.9 | 3.89
AZI-CQ14Pd/NhH3-E(O)
AZI-CQ14Pd/NhH3-E(I)
1 phase 14.2 | 13.9 4.77 | 3.74 11.9 | 13.5 2.77 | 3.57
AZI-CQ16Pd/NhH3-E1(O)
AZI-CQ16Pd/NhH3-E(I)
1 phase 16 | 16 4.55 | 3.65 13.5 | 14.9 2.65 | 3.7
AZI-CQ16Pd/NhH3-M1(O)
AZI-CQ16Pd/NhH3-M(I)
3 phase 16 | 16 4.6 | 3.7 13.5 | 14.9 2.65 | 3.6

Source: Deltron Azuri residential and commercial series catalogue (June 2026), p. 19.

Installation data

Outdoor unit Refrigerant pipes Mounting distance Outdoor power supply (cable · circuit breaker) Indoor power supply (cable · circuit breaker)
AZI-CQ6.0Pd/NhH3-E(O) ø6.35 / 12.7 mm 610 mm 3 x 1.5 mm² · 16 A 3 x 6 mm² · 20 A
AZI-CQ8.0Pd/NhH3-E(O) ø9.52 / 15.88 mm 755 mm 3 x 6 mm² · 25 A 3 x 6 mm² · 40 A
AZI-CQ10Pd/NhH3-E(O) ø9.52 / 15.88 mm 755 mm 3 x 6 mm² · 25 A 3 x 6 mm² · 40 A
AZI-CQ12Pd/NhH3-E(O) ø9.52 / 15.88 mm 755 mm 3 x 6 mm² · 40 A 3 x 6 mm² · 40 A
AZI-CQ14Pd/NhH3-E(O) ø9.52 / 15.88 mm 755 mm 3 x 6 mm² · 40 A 3 x 6 mm² · 40 A
AZI-CQ16Pd/NhH3-E1(O) ø9.52 / 15.88 mm 572 mm 3 x 6 mm² · 40 A 3 x 6 mm² · 40 A
AZI-CQ16Pd/NhH3-M1(O) ø9.52 / 15.88 mm 572 mm 5 x 2.5 mm² · 16 A 5 x 4 mm² · 20 A

Source: Deltron Azuri residential and commercial series catalogue (June 2026), p. 27 (technical data).

Comparison of models in the series

  • The 6 kW model uses ø6.35 / 12.7 mm pipes and up to 20 m of piping; the 8–16 kW models use ø9.52 / 15.88 mm pipes and up to 30 m.
  • The 8 kW model has the highest COP at A7/W35 (5.30), while the 6 kW model has the highest COP at A7/W45 (4.00).
  • The 16 kW model is also available in a three-phase version (M1 outdoor unit).

Comparison with other series

Azuri air-to-water heat pumps from the same catalogue.

Series Version Refrigerant Water outlet (heating/DHW) Heating up to Performance DHW tank
Vezuri V monoblock monoblock R290 20–80 °C −25 °C 4–16 kW —
Vezuri IV monoblock monoblock R32 20–65 °C −25 °C 6–16 kW —
Vezuri IV monoblok Max monoblok R32 20–65 °C −25 °C 18–30 kW (3 phase) —
Vezuri IV split outdoor + hydrobox R32 20–65 °C −30 °C 6–16 kW separate
Vezuri IV All in One outdoor + module with tank R32 20–65 °C −30 °C 4–16 kW 190 L built-in

Values from the Deltron catalogue. Outlet water = water temperature range for heating/DHW according to the catalogue icons; cooling: 5–25 °C for all series.

Which series is right for you

Vezuri V monoblok (R290)
When the highest water temperature (up to 80 °C) and natural refrigerant R290 are priorities. The entire cooling circuit is in the outdoor unit, with only water connections entering the house.
View the series →
Vezuri IV monoblok (R32)
For heating, cooling, and DHW up to 65 °C with underfloor heating, low-temperature radiators, or fan coil units, without cooling water in the house. Also available in a three-phase version.
View the series →
Vezuri IV monoblok Max
For higher heating requirements: 18–30 kW, three-phase power supply only.
Vezuri IV split · this series
When the hydraulics need to be in the house (wall-mounted hydrobox), and the outdoor unit is connected with cooling water. Water does not leave the building; guaranteed heating operation down to −30 °C.
Vezuri IV All in One
When everything is wanted in a single indoor unit: a hydraulic module and a 190 L DHW tank, along with an outdoor unit.
View the series →

Monoblok, split, or All in One

Monoblok Split (hydrobox) All in One
Enters the house water cooling water cooling water
Indoor unit — hydrobox (wall-mounted) module with 190 L tank
DHW tank separate separate built-in
Heating down to (catalogue) −25 °C −30 °C −30 °C

What is included in the delivery

Set: outdoor unit and indoor unit (hydrobox). The price refers to the complete set of outdoor and indoor units. Refrigerant pipes, interconnections, and hydraulic accessories are not included in the delivery.

Variant designations

  • 6 kW / 1 phase: indoor AZI-CQ6.0Pd/NhH3-E(I) + outdoor AZI-CQ6.0Pd/NhH3-E(O)
  • 8 kW / 1 phase: indoor AZI-CQ8.0Pd/NhH3-E(I) + outdoor AZI-CQ8.0Pd/NhH3-E(O)
  • 10 kW / 1 phase: indoor AZI-CQ10Pd/NhH3-E(I) + outdoor AZI-CQ10Pd/NhH3-E(O)
  • 12 kW / 1 phase: indoor AZI-CQ12Pd/NhH3-E(I) + outdoor AZI-CQ12Pd/NhH3-E(O)
  • 14 kW / 1 phase: indoor AZI-CQ14Pd/NhH3-E(I) + outdoor AZI-CQ14Pd/NhH3-E(O)
  • 16 kW / 1 phase: indoor AZI-CQ16Pd/NhH3-E(I) + outdoor AZI-CQ16Pd/NhH3-E1(O)
  • 16 kW / 3 phases: indoor AZI-CQ16Pd/NhH3-M(I) + outdoor AZI-CQ16Pd/NhH3-M1(O)
Technical data is taken from the Deltron catalogue (importer). Source: Deltron catalogue of Azuri residential and commercial series (June 2026). Please check the availability of individual units before ordering.