Mitsubishi Electric Ecodan Eco Inverter split dizalica topline s hidroboxom (komplet)

Mitsubishi Electric Ecodan Eco Inverter split heat pump with hydronbox (set)

4 kW
€5.888,31
Skip to product information
Mitsubishi Electric Ecodan Eco Inverter split dizalica topline s hidroboxom (komplet)
1/3

Mitsubishi Electric

Mitsubishi Electric Ecodan Eco Inverter split heat pump with hydronbox (set)

Šifra modela: ERSD-VM2E / SUZ-SWM40VA2

€5.888,31
Sidrena cijena: €5.888,31
Dostupnost Dostupno Za naručivanje
Informacijski list proizvoda
Energetska oznaka
Otvori oznaku (PDF) u novoj kartici
Strength

Cijena vrijedi za jednokratno plaćanje debitnom/kreditnom karticom ili virmanom.

Platite virmanom – 2D barkod stiže u e-mailu Nakon narudžbe skenirajte barkod u aplikaciji svoje banke („Slikaj i plati”) i uplata je gotova u par sekundi.
Dostava Zagreb: 1–3 radna danaDostava Hrvatska (osim otoka): 1–7 radnih danaOtoci – na upit
Ovlaštena montaža – vlastiti montažni timovi
Niste sigurni? Pozovite ili pišite na WhatsApp
Imate pitanje o ovoj klimi? Pitajte nas na WhatsApp Radno vrijeme: pon–pet 8–16 h
Dokumenti za preuzimanje
Energetska oznaka
Preuzmi PDF
Informacijski list
Preuzmi PDF
Osnovne informacije
Proizvođač
Mitsubishi-electric
Šifra modela
ERSD-VM2E / SUZ-SWM40VA2
Tehnički podaci
Tehnički podaci – 4 kW
Općenito
BrandMitsubishi Electric
Model unutarnje jediniceERSD-VM2E
Model vanjske jediniceSUZ-SWM40VA2
Radna tvarR32
Učinak i učinkovitost
Nazivni učin grijanja (kW)3,0
SCOP (35 °C / 55 °C)5,06 / 3,45
Područje rada hlađenje (°C)od +10 do +46
Područje rada grijanje (°C)od −25 do +24
Buka
Zvučna snaga vanjske jedinice (dB(A))57
Dimenzije i masa
Dimenzije vanjske jedinice V × Š × D (mm)714 × 800 × 285
Težina vanjske jedinice (kg)39,0
Instalacija
Napajanje1-fazno, 230 V

Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.

The Mitsubishi Electric Ecodan Eco Inverter split is an air-to-water heat pump using R32 refrigerant for space heating and cooling and domestic hot water preparation up to 60 °C. The indoor unit is a compact wall-mounted hydrobox (800 × 530 × 360 mm), and the domestic hot water tank can be connected optionally.

Mitsubishi Electric Ecodan Eco Inverter – ambience
60 °C
max. flow temperature
−25 °C
guaranteed heating down to
A+++
heating class 35 °C (A++ at 55 °C)
4–10 kW
rated capacity (A2/W35)

Key benefits

Domestic hot water up to 60 °C
Space heating and cooling and domestic hot water preparation.
MELCloud Home
Option to control via the MELCloud Home app (Wi-Fi interface MAC-587IF-E, optional).
Two-zone control
Two zones with different flow temperatures (e.g. radiators and underfloor heating).
SG Ready
Smart grid and photovoltaic system connection.
microSD card
Easy system configuration and data monitoring.
Quiet operation
Reduced noise level; SUZ-SWM40VA2 58 dB(A) in quiet mode (67 dB(A) normal, A-7/W35).

How it works and where it is used

The outdoor unit is connected to the indoor unit by cooling water; the water remains inside the building.

Ecodan two-zone heating diagram
Example of a two-zone system: radiators (40 °C) and underfloor heating (30 °C). The buffer tank, mixing valves and pumps are supplied locally. Source: ME catalogue 2026, p. 20 (labels translated).

The indoor unit (hydrobox) contains a plate heat exchanger, pump, auxiliary heater and control system. The E-generation main controller features a colour touch screen and displays both zones and domestic hot water on the home screen.

Indoor unit cross-section
Cross-section of an E-generation indoor unit (ME catalogue 2026, p. 18, labels translated).
Eco Inverter operating range
Eco Inverter (SUZ): guaranteed heating down to an outdoor temperature of −25 °C (ME catalogue, p. 14).

Control

E-generation main controller
E-generation main controller (ME catalogue, p. 25).
MELCloud Home
MELCloud Home – control via computer, tablet or smartphone (ME catalogue, p. 55).
SG Ready diagram
SG Ready: storing excess energy from a photovoltaic system in the domestic hot water and buffer tanks (ME catalogue, p. 24, labels translated).

Technical data

Each variant is a complete set of an outdoor and indoor unit.

Configuration split: outdoor unit + hydrobox
Refrigerant R32 (GWP 675)
Guaranteed operating range – heating −25 to +24 °C
Guaranteed operating range – domestic hot water −25 to +35 °C
Guaranteed operating range – cooling +10 to +46 °C
Max. flow temperature 60 °C
Max. domestic hot water tank temperature —
Heating energy efficiency class A+++ (35 °C) / A++ (55 °C), average climate
Max. pipe length (Deltron catalogue) 26 m (40/60), 46 m (80/100)
Outdoor + indoor unit Power supply Heating A7/W35 kW (COP) Heating A2/W35 kW (COP) Max. A−7/W35 | A−15/W35 kW Cooling A35/W7 kW (EER) Cooling A35/W18 kW (EER) Class and ηs 35 °C | 55 °C
SUZ-SWM40VA2
ERSD-VM2E
1 phase 3.0 (5.11) 4.0 (3.90) 6.5 | 4.3 4.5 (3.31) 5.6 (4.71) A+++ 200 % | A++ 135 %
SUZ-SWM60VA2
ERSD-VM2E
1 phase 5.0 (4.85) 6.0 (3.62) 7.0 | 5.0 5.0 (3.18) 6.0 (4.65) A+++ 189 % | A++ 136 %
SUZ-SWM80VA2
ERSD-VM2E
1 phase 6.0 (5.10) 7.5 (3.50) 8.0 | 7.0 6.7 (3.20) 6.7 (5.06) A+++ 187 % | A++ 135 %
SUZ-SWM100VA
ERSD-VM2E
1 phase 7.5 (4.85) 9.0 (3.12) 9.0 | 7.0 7.3 (3.00) 8.1 (4.44) A+++ 182 % | A++ 134 %

Capacity according to EN14511 (excluding circulation pump consumption); ηs according to Regulation (EU) 813/2013 for average climate; max. capacity at −7 and −15 °C from the Deltron catalogue combinations table, p. 18. Source: ME Air to Water Catalogue 2026 and Mitsubishi Electric Air to Water Catalogue 2026.

Outdoor units – dimensions and connections

Outdoor unit Dimensions H × W × D Weight Sound power (heating) Max. operating current Fuse Refrigerant pipe liquid / gas Length / vertical rise
SUZ-SWM40VA2 714 × 800 × 285 mm 39 kg 57 dB(A) 13.5 A 16 A 6.35 / 12.7 mm 2–26 m / 26 m
SUZ-SWM60VA2 714 × 800 × 285 mm 40 kg 60 dB(A) 13.5 A 16 A 6.35 / 12.7 mm 2–26 m / 26 m
SUZ-SWM80VA2 880 × 840 × 330 mm 53 kg 60 dB(A) 17.3 A 20/16 A 6.35 / 12.7 mm 2–46 m / 30 m
SUZ-SWM100VA 880 × 840 × 330 mm 53 kg 62 dB(A) 17.3 A 20/16 A 6.35 / 12.7 mm 2–46 m / 30 m

Sound power (PWL) according to EN12102. * 30 m for cooling operation at 120/140. Source: ME Air to Water Catalogue 2026, p. 51.

Indoor units

Indoor unit Type Dimensions H × W × D Weight (empty) Auxiliary heater Heating flow temperature Expansion vessel Sound power
ERSD-VM2E hidrobox 800 × 530 × 360 mm 37 kg 2 kW 20–60 °C yes 41 dB(A)

Cooling: flow 5–25 °C; max. DHW temperature in the tank 70 °C; indoor unit ambient 0–35 °C (≤ 80 % RH). Source: ME Air to Water Catalogue 2026, p. 46–47.

Comparison of models in the series

  • The power rating (e.g. 80 = 8 kW) corresponds to the nominal heating capacity at A2/W35.
  • Models 40 and 60 have a smaller enclosure (714 × 800 × 285 mm) and piping up to 26 m; 80 and 100 have a larger enclosure (880 × 840 × 330 mm) and piping up to 46 m.
  • The highest ηs at 35 °C is SUZ-SWM40VA2 (200 %).

Comparison with other series

Mitsubishi Electric Ecodan from Deltron's range.

Series Cooling Capacity / power supply Max. flow Heating up to Cooling Indoor unit
Eco Inverter (SUZ) R32 4–10 kW, 1 phase 60 °C −25 °C +10…+46 °C hidrobox or 170/200/300 L tank
Power Inverter (PUZ) R32 8–14 kW, 1 or 3 phases 68 °C −25 °C +10…+52 °C hidrobox or 200/300 L tank
Zubadan (PUZ-SHWM) R32 8–14 kW, 1 or 3 phases 70 °C −30 °C +10…+52 °C hidrobox or 200/300 L tank
Power Inverter R410A (PUHZ-SW120) R410A 12 kW, 1 phase 60 °C −20 °C −15…+46 °C hidrobox or 200 L tank
Zubadan R410A (PUHZ-SHW) R410A 8 / 11.2 / 23 kW, 3 phases 60 °C −28 °C (230: −25 °C) −15…+46 °C hidrobox
Ecodan Multi (PXZ) R32 1 air-to-air + air-to-water outdoor unit 55 °C −20 °C −10…+46 °C Ecodan hidrobox/tank (D)
Ecodan Multi Light R32 PXZ-5F85VG + tank 55 °C (65 °C with heater) −20 °C −10…+46 °C 200 L tank (stainless steel)

Values from the Deltron ME catalogue (importer) and the ME Air to Water 2026 catalogue. Heating up to = guaranteed operating heating range (outdoor temperature).

Which series is right for you

Eco Inverter · this series
The most affordable entry into the Ecodan system: smaller and medium-sized buildings (4–10 kW), single-phase connection, flow up to 60 °C.
Power Inverter
Higher flow (up to 68 °C) and higher capacities 8–14 kW, single-phase or three-phase – for radiator renovations and larger homes.
View the series →
Zubadan
For the coldest locations: Flash Injection, guaranteed heating down to −30 °C and flow up to 70 °C.
View the series →
Hidrobox or tank
Hidrobox (800 × 530 × 360 mm) is wall-mounted and leaves the choice of tank free; the tank version has an integrated 170/200/300 L stainless steel DHW tank.
View the tank version →
Ecodan Multi / Multi Light
One outdoor unit for air-to-air air conditioning and Ecodan water heating or DHW – fewer outdoor units on the facade.
View the series →

Hidrobox or tank

Hidrobox Indoor unit with tank
Dimensions 800 × 530 × 360 mm (wall-mounted) 1400 / 1600 / 2050 × 595 × 680 mm (floor-standing)
DHW separate tank of your choice integrated 170 / 200 / 300 l tank
Advantage little wall space, freedom of tank choice everything in one enclosure, factory assembled

What is included

Set: outdoor unit and indoor unit (hidrobox) according to the variant. The price is for the complete set. Wi-Fi interface, wireless controller, sensors and dual-zone set are optional.

Variant designations

  • 4 kW: indoor ERSD-VM2E + outdoor SUZ-SWM40VA2
  • 6 kW: indoor ERSD-VM2E + outdoor SUZ-SWM60VA2
  • 8 kW: indoor ERSD-VM2E + outdoor SUZ-SWM80VA2
  • 10 kW: indoor ERSD-VM2E + outdoor SUZ-SWM100VA
Technical data is taken from the Deltron catalogue (importer) and the Mitsubishi Electric Air to Water 2026 catalogue (translated by KlimaProdaja). Please check the availability of the individual unit before ordering.