Mitsubishi Electric Ecodan Eco Inverter split dizalica topline sa spremnikom PTV-a (komplet)

Mitsubishi Electric Ecodan Eco Inverter split heat pump with hot water tank (complete set)

4 kW / 170 L
€8.325,81
Skip to product information
Mitsubishi Electric Ecodan Eco Inverter split dizalica topline sa spremnikom PTV-a (komplet)
1/3

Mitsubishi Electric

Mitsubishi Electric Ecodan Eco Inverter split heat pump with hot water tank (complete set)

Šifra modela: ERST17D-VM2E / SUZ-SWM40VA2

€8.325,81
Sidrena cijena: €8.325,81
Dostupnost Dostupno Za naručivanje
Informacijski list proizvoda
Energetska oznaka
Otvori oznaku (PDF) u novoj kartici
Strength
Tank volume

Cijena vrijedi za jednokratno plaćanje debitnom/kreditnom karticom ili virmanom.

Platite virmanom – 2D barkod stiže u e-mailu Nakon narudžbe skenirajte barkod u aplikaciji svoje banke („Slikaj i plati”) i uplata je gotova u par sekundi.
Dostava Zagreb: 1–3 radna danaDostava Hrvatska (osim otoka): 1–7 radnih danaOtoci – na upit
Ovlaštena montaža – vlastiti montažni timovi
Niste sigurni? Pozovite ili pišite na WhatsApp
Imate pitanje o ovoj klimi? Pitajte nas na WhatsApp Radno vrijeme: pon–pet 8–16 h
Dokumenti za preuzimanje
Energetska oznaka
Preuzmi PDF
Informacijski list
Preuzmi PDF
Osnovne informacije
Proizvođač
Mitsubishi-electric
Šifra modela
ERST17D-VM2E / SUZ-SWM40VA2
Tehnički podaci
Tehnički podaci – 4 kW / 170 L
Općenito
BrandMitsubishi Electric
Model unutarnje jediniceERST17D-VM2E
Model vanjske jediniceSUZ-SWM40VA2
Radna tvarR32
Učinak i učinkovitost
Nazivni učin grijanja (kW)3,0
SCOP (35 °C / 55 °C)5,06 / 3,45
Područje rada hlađenje (°C)od +10 do +46
Područje rada grijanje (°C)od −25 do +24
Buka
Zvučna snaga vanjske jedinice (dB(A))57
Dimenzije i masa
Dimenzije vanjske jedinice V × Š × D (mm)714 × 800 × 285
Težina vanjske jedinice (kg)39,0
Instalacija
Napajanje1-fazno, 230 V

Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.

The Mitsubishi Electric Ecodan Eco Inverter split is an air-to-water heat pump using R32 refrigerant for space heating and cooling, and domestic hot water production up to 60 °C. The indoor unit has an integrated DHW tank with a capacity of 170 / 200 / 300 l, so the entire system is housed in one compact casing.

Mitsubishi Electric Ecodan Eco Inverter – setting
60 °C
max. flow temperature
−25 °C
guaranteed heating down to
A+++
heating class at 35 °C (A++ at 55 °C)
4–10 kW
rated capacity (A2/W35)

Key benefits

DHW up to 60 °C
Space heating and cooling, plus domestic hot water production.
MELCloud Home
Can be controlled via the MELCloud Home app (MAC-587IF-E Wi-Fi interface, optional).
Two-zone control
Two zones with different flow temperatures (e.g. radiators and underfloor heating).
SG Ready
Connection to a smart grid and photovoltaic system.
microSD card
Easy system setup and data monitoring.
Quiet mode
Reduced noise level; SUZ-SWM40VA2: 58 dB(A) in quiet mode (67 dB(A) normal, A-7/W35).

How it works and where it is used

The outdoor unit is connected to the indoor unit by refrigerant lines; water remains inside the house.

Ecodan two-zone heating diagram
Example of a two-zone system: radiators (40 °C) and underfloor heating (30 °C). The buffer tank, mixing valves and pumps are sourced locally. Source: ME catalogue 2026, p. 20 (labels translated).

The indoor unit (tank) contains a plate heat exchanger, pump, auxiliary heater and controls. The E-generation main controller has a colour touchscreen and displays both zones and DHW on the home screen.

Cross-section of the indoor unit
Cross-section of the E-generation indoor unit (ME catalogue 2026, p. 18, labels translated).
Eco Inverter operating range
Eco Inverter (SUZ): guaranteed heating down to an outdoor temperature of −25 °C (ME catalogue, p. 14).

Controls

E-generation main controller
E-generation main controller (ME catalogue, p. 25).
MELCloud Home
MELCloud Home – control via computer, tablet or smartphone (ME catalogue, p. 55).
SG Ready diagram
SG Ready: storing surplus energy from a photovoltaic system in the DHW and buffer tanks (ME catalogue, p. 24, labels translated).

Technical data

Each version is a complete set comprising an outdoor and an indoor unit.

Configuration split: outdoor unit + indoor unit with DHW tank
Refrigerant R32 (GWP 675)
Guaranteed operating range – heating −25 to +24 °C
Guaranteed operating range – DHW −25 to +35 °C
Guaranteed operating range – cooling +10 to +46 °C
Max. flow temperature 60 °C
Max. DHW temperature in tank 70 °C
Heating energy efficiency class A+++ (35 °C) / A++ (55 °C), average climate
Max. pipe length (Deltron catalogue) 26 m (40/60), 46 m (80/100)
Outdoor + indoor unit Power supply Heating A7/W35 kW (COP) Heating A2/W35 kW (COP) Max. A−7/W35 | A−15/W35 kW Cooling A35/W7 kW (EER) Cooling A35/W18 kW (EER) Class and ηs 35 °C | 55 °C DHW class / ηwh
SUZ-SWM40VA2
ERST17D-VM2E
1-phase 3,0 (5,11) 4,0 (3,90) 6,5 | 4,3 4,5 (3,31) 5,6 (4,71) A+++ 200 % | A++ 135 % A+ / 136 %
SUZ-SWM60VA2
ERST17D-VM2E
1-phase 5,0 (4,85) 6,0 (3,62) 7,0 | 5,0 5,0 (3,18) 6,0 (4,65) A+++ 189 % | A++ 136 % A+ / 135 %
SUZ-SWM80VA2
ERST17D-VM2E
1-phase 6,0 (5,10) 7,5 (3,50) 8,0 | 7,0 6,7 (3,20) 6,7 (5,06) A+++ 187 % | A++ 135 % A+ / 140 %
SUZ-SWM100VA
ERST17D-VM2E
1-phase 7,5 (4,85) 9,0 (3,12) 9,0 | 7,0 7,3 (3,00) 8,1 (4,44) A+++ 182 % | A++ 134 % A+ / 140 %
SUZ-SWM40VA2
ERST20D-VM2E
1-phase 3,0 (5,11) 4,0 (3,90) 6,5 | 4,3 4,5 (3,31) 5,6 (4,71) A+++ 200 % | A++ 135 % A+ / 151 %
SUZ-SWM60VA2
ERST20D-VM2E
1-phase 5,0 (4,85) 6,0 (3,62) 7,0 | 5,0 5,0 (3,18) 6,0 (4,65) A+++ 189 % | A++ 136 % A+ / 153 %
SUZ-SWM80VA2
ERST20D-VM2E
1-phase 6,0 (5,10) 7,5 (3,50) 8,0 | 7,0 6,7 (3,20) 6,7 (5,06) A+++ 187 % | A++ 135 % A+ / 148 %
SUZ-SWM100VA
ERST20D-VM2E
1-phase 7,5 (4,85) 9,0 (3,12) 9,0 | 7,0 7,3 (3,00) 8,1 (4,44) A+++ 182 % | A++ 134 % A+ / 148 %
SUZ-SWM40VA2
ERST30D-VM2EE
1-phase 3,0 (5,11) 4,0 (3,90) 6,5 | 4,3 4,5 (3,31) 5,6 (4,71) A+++ 200 % | A++ 135 % A+ / 126 %
SUZ-SWM60VA2
ERST30D-VM2EE
1-phase 5,0 (4,85) 6,0 (3,62) 7,0 | 5,0 5,0 (3,18) 6,0 (4,65) A+++ 189 % | A++ 136 % A+ / 125 %
SUZ-SWM80VA2
ERST30D-VM2EE
1-phase 6,0 (5,10) 7,5 (3,50) 8,0 | 7,0 6,7 (3,20) 6,7 (5,06) A+++ 187 % | A++ 135 % A+ / 125 %
SUZ-SWM100VA
ERST30D-VM2EE
1 phase 7.5 (4.85) 9.0 (3.12) 9.0 | 7.0 7.3 (3.00) 8.1 (4.44) A+++ 182 % | A++ 134 % A+ / 125 %

Performance according to EN14511 (without circulation pump consumption); ηs according to Regulation (EU) 813/2013 for average climate; max. performance at −7 and −15 °C from the Deltron catalogue combination table, p. 18. Source: Deltron Mitsubishi Electric heat pump catalogue (June 2026) and Mitsubishi Electric Air to Water Catalogue 2026.

Outdoor units – dimensions and connections

Outdoor unit Dimensions H × W × D Weight Acoustic power (heating) Max. operating current Fuse Refrigerant pipes liquid / gas Length / height difference
SUZ-SWM40VA2 714 × 800 × 285 mm 39 kg 57 dB(A) 13.5 A 16 A 6.35 / 12.7 mm 2–26 m / 26 m
SUZ-SWM60VA2 714 × 800 × 285 mm 40 kg 60 dB(A) 13.5 A 16 A 6.35 / 12.7 mm 2–26 m / 26 m
SUZ-SWM80VA2 880 × 840 × 330 mm 53 kg 60 dB(A) 17.3 A 20/16 A 6.35 / 12.7 mm 2–46 m / 30 m
SUZ-SWM100VA 880 × 840 × 330 mm 53 kg 62 dB(A) 17.3 A 20/16 A 6.35 / 12.7 mm 2–46 m / 30 m

Acoustic power (PWL) according to EN12102. * 30 m for cooling operation at 120/140. Source: ME Air to Water Catalogue 2026, p. 51.

Indoor units

Indoor unit Type Dimensions H × W × D Weight (empty) Auxiliary heater Heating flow temperature Expansion vessel Acoustic power
ERST17D-VM2E 170 l tank 1400 × 595 × 680 mm 91 kg 2 kW 20–60 °C yes 41 dB(A)
ERST20D-VM2E 200 l tank 1600 × 595 × 680 mm 94 kg 2 kW 20–60 °C yes 41 dB(A)
ERST30D-VM2EE 300 l tank 2050 × 595 × 680 mm 108 kg 2 kW 20–60 °C no 41 dB(A)

Cooling: flow 5–25 °C; max. tank DH temperature 70 °C; indoor unit ambient 0–35 °C (≤ 80 % RH). Source: ME Air to Water Catalogue 2026, p. 46–47.

Comparison of models in the series

  • The power rating (e.g. 80 = 8 kW) corresponds to the nominal heating capacity at A2/W35.
  • Models 40 and 60 have a smaller cabinet (714 × 800 × 285 mm) and piping up to 26 m; 80 and 100 have a larger cabinet (880 × 840 × 330 mm) and piping up to 46 m.
  • The highest ηs at 35 °C is SUZ-SWM40VA2 (200 %).
  • The 300 l tank (ERST30) does not have an integrated expansion vessel and is taller (2050 mm); the 200 l is 1600 mm high, the 170 l is 1400 mm.

Comparison with other series

Mitsubishi Electric Ecodan from the Deltron range.

Series Refrigerant Capacity / power supply Max. flow Heating up to Cooling Indoor unit
Eco Inverter (SUZ) R32 4–10 kW, 1 phase 60 °C −25 °C +10…+46 °C hydrobox or 170/200/300 L tank
Power Inverter (PUZ) R32 8–14 kW, 1 or 3 phases 68 °C −25 °C +10…+52 °C hydrobox or 200/300 L tank
Zubadan (PUZ-SHWM) R32 8–14 kW, 1 or 3 phases 70 °C −30 °C +10…+52 °C hydrobox or 200/300 L tank
Power Inverter R410A (PUHZ-SW120) R410A 12 kW, 1 phase 60 °C −20 °C −15…+46 °C hydrobox or 200 L tank
Zubadan R410A (PUHZ-SHW) R410A 8 / 11.2 / 23 kW, 3 phases 60 °C −28 °C (230: −25 °C) −15…+46 °C hydrobox
Ecodan Multi (PXZ) R32 1 outdoor unit for air-to-air + air-to-water 55 °C −20 °C −10…+46 °C Ecodan hydrobox/tank (D)
Ecodan Multi Light R32 PXZ-5F85VG + tank 55 °C (65 °C with heater) −20 °C −10…+46 °C 200 L tank (stainless steel)

Values from the ME Deltron catalogue (June 2026) and ME Air to Water Catalogue 2026. Heating up to = guaranteed operating heating range (outdoor temperature).

Which series is right for you

Eco Inverter · this series
The most affordable entry into the Ecodan system: small and medium-sized buildings (4–10 kW), single-phase connection, flow up to 60 °C.
Power Inverter
Higher flow (up to 68 °C) and higher capacities 8–14 kW, single-phase or three-phase – for radiator retrofits and larger homes.
View the series →
Zubadan
For the coldest locations: Flash Injection, guaranteed heating down to −30 °C and flow up to 70 °C.
View the series →
Hydrobox or tank
Hydrobox (800 × 530 × 360 mm) is wall-mounted and leaves the choice of tank open; the tank version has an integrated 170/200/300 L stainless steel DHV tank.
View the hydrobox version →
Ecodan Multi / Multi Light
One outdoor unit for air-to-air air conditioners and Ecodan water heating or DHV – fewer outdoor units on the facade.
View the series →

Hydrobox or tank

Hydrobox Indoor unit with tank
Dimensions 800 × 530 × 360 mm (wall-mounted) 1400 / 1600 / 2050 × 595 × 680 mm (floor-standing)
DHV separate tank of your choice integrated tank 170 / 200 / 300 l
Advantage little wall space, freedom to choose the tank everything in one enclosure, factory assembled

What is included

Set: outdoor unit and indoor unit (with heat pump tank) according to the variant. The price is for the complete set. Wi-Fi interface, wireless controller, sensors and dual-zone set are optional.

Variant designations

  • 4 kW / 170 L: indoor ERST17D-VM2E + outdoor SUZ-SWM40VA2
  • 6 kW / 170 L: indoor ERST17D-VM2E + outdoor SUZ-SWM60VA2
  • 8 kW / 170 L: indoor ERST17D-VM2E + outdoor SUZ-SWM80VA2
  • 10 kW / 170 L: indoor ERST17D-VM2E + outdoor SUZ-SWM100VA
  • 4 kW / 200 L: indoor ERST20D-VM2E + outdoor SUZ-SWM40VA2
  • 6 kW / 200 L: indoor ERST20D-VM2E + outdoor SUZ-SWM60VA2
  • 8 kW / 200 L: indoor ERST20D-VM2E + outdoor SUZ-SWM80VA2
  • 10 kW / 200 L: indoor ERST20D-VM2E + outdoor SUZ-SWM100VA
  • 4 kW / 300 L: indoor ERST30D-VM2EE + outdoor SUZ-SWM40VA2
  • 6 kW / 300 L: indoor ERST30D-VM2EE + outdoor SUZ-SWM60VA2
  • 8 kW / 300 L: indoor ERST30D-VM2EE + outdoor SUZ-SWM80VA2
  • 10 kW / 300 L: indoor ERST30D-VM2EE + outdoor SUZ-SWM100VA
Technical data is taken from the Deltron catalog (importer) and the Mitsubishi Electric Air to Water 2026 catalog (translated by KlimaProdaja). Please check the availability of the individual device before ordering.

Možda će vam se također svidjeti