Mitsubishi Electric Ecodan Zubadan split dizalica topline sa spremnikom PTV-a (komplet)

Mitsubishi Electric Ecodan Zubadan split heat pump with hot water tank (set)

8 kW / Phase 1 / 200 L
€12.825,00
Skip to product information
Mitsubishi Electric Ecodan Zubadan split dizalica topline sa spremnikom PTV-a (komplet)
1/3

Mitsubishi Electric

Mitsubishi Electric Ecodan Zubadan split heat pump with hot water tank (set)

Šifra modela: ERST20F-VM2E / PUZ-SHWM80VAA

€12.825,00
Sidrena cijena: €12.825,00
Dostupnost Dostupno Za naručivanje
Informacijski list proizvoda
Energetska oznaka
Otvori oznaku (PDF) u novoj kartici
Strength
Power supply
Tank volume

Montažu ovog uređaja dogovaramo na upit, prema mjestu ugradnje. Javite nam se za ponudu.

Cijena vrijedi za jednokratno plaćanje debitnom/kreditnom karticom ili virmanom.

Platite virmanom – 2D barkod stiže u e-mailu Nakon narudžbe skenirajte barkod u aplikaciji svoje banke („Slikaj i plati”) i uplata je gotova u par sekundi.
Dostava Zagreb: 1–3 radna danaDostava Hrvatska (osim otoka): 1–7 radnih danaOtoci – na upit
Ovlaštena montaža – vlastiti montažni timovi
Niste sigurni? Pozovite ili pišite na WhatsApp
Imate pitanje o ovoj klimi? Pitajte nas na WhatsApp Radno vrijeme: pon–pet 8–16 h
Dokumenti za preuzimanje
Energetska oznaka
Preuzmi PDF
Informacijski list
Preuzmi PDF
Osnovne informacije
Proizvođač
Mitsubishi-electric
Šifra modela
ERST20F-VM2E / PUZ-SHWM80VAA
Tehnički podaci
Tehnički podaci – 8 kW / Phase 1 / 200 L
Općenito
BrandMitsubishi Electric
Model unutarnje jediniceERST20F-VM2E
Model vanjske jedinicePUZ-SHWM80VAA
Radna tvarR32
Učinak i učinkovitost
Kapacitet hlađenja (kW)7,1
Nazivni učin grijanja (kW)6,0
SCOP (35 °C / 55 °C)4,77 / 3,42
Energetski razred grijanja (35 °C / 55 °C)A+++ / A++
Volumen spremnika (L)200
Buka
Zvučna snaga vanjske jedinice (dB(A))54
Dimenzije i masa
Težina vanjske jedinice (kg)106,0
Instalacija
Napajanje1-fazno, 230 V

Izvor: podaci proizvođača i ovlaštenih distributera; energetski razredi, SEER i SCOP provjereni u EU bazi energetskih oznaka (EPREL) gdje je dostupno.

The Mitsubishi Electric Ecodan Zubadan split is an air-to-water heat pump using R32 refrigerant for space heating and cooling, and for preparing domestic hot water up to 70 °C. The indoor unit has an integrated 200 / 300 l domestic hot water tank, so the entire system is housed in a single compact unit. Flash Injection technology ensures efficient heating down to −30 °C.

Mitsubishi Electric Ecodan Zubadan – ambience
70 °C
max. flow temperature
−30 °C
guaranteed heating down to
A+++
heating class 35 °C (A++ at 55 °C)
8–14 kW
nominal capacity (A2/W35)

Key Benefits

Flash Injection down to −30 °C
Guaranteed heating operation down to −30 °C and 70 °C flow at an outdoor temperature of −7 °C (ΔT 10 °C, pipes up to 15 m).
MELCloud Home
Control via the MELCloud Home app (MAC-587IF-E Wi-Fi interface, optional).
Dual-zone control
Two zones with different flow temperatures (e.g. radiators and underfloor heating).
SG Ready
Smart grid and photovoltaic system connection.
microSD card
Easy system configuration and data monitoring.
Quiet operation
Three noise reduction levels (PUZ).

How it works and where it is used

The outdoor unit is connected to the indoor unit by refrigerant piping; the water remains inside the building.

Ecodan dual-zone heating diagram
Example of a dual-zone system: radiators (40 °C) and underfloor heating (30 °C). The buffer tank, mixing valves and pumps are sourced locally. Source: ME catalogue 2026, p. 20 (labels translated).

The indoor unit (tank) contains a plate heat exchanger, pump, auxiliary heater and control system. The E-generation main controller features a touch-sensitive colour display showing both zones and the domestic hot water on the home screen.

Cross-section of the indoor unit
Cross-section of an E-generation indoor unit (ME catalogue 2026, p. 18, labels translated).
ZUBADAN operating area
Guaranteed heating operating range: standard down to −25 °C, ZUBADAN down to −30 °C (ME catalogue, p. 17).
Flash Injection cycle
Flash Injection cycle: injecting additional refrigerant into the compressor increases heating capacity at low temperatures (ME catalogue, p. 17).

Control

E-generation main controller
E-generation main controller (ME catalogue, p. 25).
MELCloud Home
MELCloud Home – control via computer, tablet or smartphone (ME catalogue, p. 55).
SG Ready diagram
SG Ready: storing excess energy from a photovoltaic system in the domestic hot water tank and buffer tank (ME catalogue, p. 24, labels translated).

Technical data

Each variant is a complete outdoor and indoor unit.

Configuration split: outdoor unit + indoor unit with domestic hot water tank
Refrigerant R32 (GWP 675)
Guaranteed operating range – heating −30 to +24 °C
Guaranteed operating range – domestic hot water −30 to +42 °C
Guaranteed operating range – cooling +10 to +52 °C
Max. flow temperature 70 °C (at ΔT 10 °C and pipes up to 15 m; otherwise 68 °C)
Max. domestic hot water tank temperature 70 °C
Heating energy efficiency class A+++ (35 °C) / A++ (55 °C), average climate
Max. piping length (Deltron catalogue) 50 m (80/100), 30/50 m (120/140)*
Outdoor + indoor unit Power supply Heating A7/W35 kW (COP) Heating A2/W35 kW (COP) Max. A−7/W35 | A−15/W35 kW Cooling A35/W7 kW (EER) Cooling A35/W18 kW (EER) Class and ηs 35 °C | 55 °C Domestic hot water class / ηwh
PUZ-SHWM80VAA
ERST20F-VM2E
1 phase 6.0 (5.05) 8.0 (3.80) 10.0 | 8.8 7.1 (3.30) 8.0 (4.95) A+++ 188 % | A++ 134 % A+ / 137 %
PUZ-SHWM100VAA
ERST20F-VM2E
1 phase 8.0 (5.05) 10.0 (3.55) 13.2 | 10.7 9.0 (3.00) 10.0 (4.50) A+++ 186 % | A++ 138 % A+ / 125 %
PUZ-SHWM120VAA
ERST20F-VM2E
1 phase 10.0 (4.90) 12.1 (3.35) 14.9 | 12.3 11.0 (2.86) 12.0 (4.50) A+++ 182 % | A++ 138 % A+ / 125 %
PUZ-SHWM140VAA
ERST20F-VM2E
1 phase 12.0 (4.85) 14.0 (3.30) 15.8 | 14.2 12.5 (2.62) 14.0 (3.75) A+++ 185 % | A++ 142 % A / 112 %
PUZ-SHWM80YAA
ERST30F-VM2EE
3 phases 6.0 (5.05) 8.0 (3.80) 10.0 | 8.8 7.1 (3.30) 8.0 (4.95) A+++ 187 % | A++ 133 % A+ / 137 %
PUZ-SHWM100YAA
ERST30F-YM9E
3 phases 8.0 (5.05) 10.0 (3.55) 13.2 | 10.7 9.0 (3.00) 10.0 (4.50) A+++ 186 % | A++ 138 % A+ / 125 %
PUZ-SHWM120YAA
ERST30F-YM9E
3 phases 10.0 (4.90) 12.1 (3.35) 14.9 | 12.3 11.0 (2.86) 12.0 (4.50) A+++ 182 % | A++ 138 % A+ / 125 %
PUZ-SHWM140YAA
ERST30F-YM9E
3 phases 12.0 (4.85) 14.0 (3.30) 15.8 | 14.2 12.5 (2.62) 14.0 (3.75) A+++ 185 % | A++ 142 % A / 112 %
PUZ-SHWM80YAA
ERST20F-YM9E
3 phases 6.0 (5.05) 8.0 (3.80) 10.0 | 8.8 7.1 (3.30) 8.0 (4.95) A+++ 187 % | A++ 133 % A+ / 137 %
PUZ-SHWM100YAA
ERST20F-YM9E
3 phases 8.0 (5.05) 10.0 (3.55) 13.2 | 10.7 9.0 (3.00) 10.0 (4.50) A+++ 186 % | A++ 138 % A+ / 137 %
PUZ-SHWM120YAA
ERST20F-YM9E
3 phases 10.0 (4.90) 12.1 (3.35) 14.9 | 12.3 11.0 (2.86) 12.0 (4.50) A+++ 182 % | A++ 138 % A+ / 137 %
PUZ-SHWM140YAA
ERST20F-YM9E
3 phases 12.0 (4.85) 14.0 (3.30) 15.8 | 14.2 12.5 (2.62) 14.0 (3.75) A+++ 185 % | A++ 142 % A+ / 131 %
PUZ-SHWM80YAA
ERST30F-YM9EE
3 phases 6.0 (5.05) 8.0 (3.80) 10.0 | 8.8 7.1 (3.30) 8.0 (4.95) A+++ 187 % | A++ 133 % A+ / 125 %
PUZ-SHWM100YAA
ERST30F-YM9EE
3 phases 8.0 (5.05) 10.0 (3.55) 13.2 | 10.7 9.0 (3.00) 10.0 (4.50) A+++ 186 % | A++ 138 % A+ / 125 %
PUZ-SHWM120YAA
ERST30F-YM9EE
3 phases 10.0 (4.90) 12.1 (3.35) 14.9 | 12.3 11.0 (2.86) 12.0 (4.50) A+++ 182 % | A++ 138 % A+ / 125 %
PUZ-SHWM140YAA
ERST30F-YM9EE
3 phases 12.0 (4.85) 14.0 (3.30) 15.8 | 14.2 12.5 (2.62) 14.0 (3.75) A+++ 185 % | A++ 142 % A / 112 %

Performance according to EN14511 (excluding circulation pump consumption); ηs according to Regulation (EU) 813/2013 for average climate; max. performance at −7 and −15 °C from the Deltron catalogue combination table, p. 18. Source: Deltron Mitsubishi Electric heat pump catalogue (June 2026) and Mitsubishi Electric Air to Water Catalogue 2026.

Outdoor units – dimensions and connections

Outdoor unit Dimensions H × W × D Weight Acoustic power (heating) Max. operating current Circuit breaker Refrigerant pipes liquid / gas Length / height difference
PUZ-SHWM80VAA 1040 × 1050 × 480 mm 106 kg 54 dB(A) 19 A 25 A 6.35 / 12.7 (15.88 for cooling) mm 50 m / 30 m
PUZ-SHWM100VAA 1040 × 1050 × 480 mm 106.5 kg 58 dB(A) 27 A 30 A 6.35 / 12.7 (15.88 for cooling) mm 50 m / 30 m
PUZ-SHWM120VAA 1040 × 1050 × 480 mm 113.5 kg 58 dB(A) 28 A 32 A 6.35 / 12.7 (15.88 for cooling) mm 30/50 m* / 30 m
PUZ-SHWM140VAA 1040 × 1050 × 480 mm 114.5 kg 58 dB(A) 35 A 40 A 6.35 / 12.7 (15.88 for cooling) mm 30/50 m* / 30 m
PUZ-SHWM80YAA 1040 × 1050 × 480 mm 115 kg 54 dB(A) 8 A 16 A 6.35 / 12.7 (15.88 for cooling) mm 50 m / 30 m
PUZ-SHWM100YAA 1040 × 1050 × 480 mm 115 kg 58 dB(A) 9 A 16 A 6.35 / 12.7 (15.88 for cooling) mm 50 m / 30 m
PUZ-SHWM120YAA 1040 × 1050 × 480 mm 125.5 kg 58 dB(A) 12 A 16 A 6.35 / 12.7 (15.88 for cooling) mm 30/50 m* / 30 m
PUZ-SHWM140YAA 1040 × 1050 × 480 mm 126 kg 58 dB(A) 12 A 16 A 6.35 / 12.7 (15.88 for cooling) mm 30/50 m* / 30 m

Acoustic power (PWL) according to EN12102. * 30 m for cooling operation for the 120/140. Source: ME Air to Water Catalogue 2026, p. 51.

Indoor units

Indoor unit Type Dimensions H × W × D Weight (empty) Auxiliary heater Heating range Expansion vessel Acoustic power
ERST20F-VM2E 200 l tank 1600 × 595 × 680 mm 94 kg 2 kW 20–70 °C yes 41 dB(A)
ERST20F-YM9E 200 l tank 1600 × 595 × 680 mm 98 kg 9 (3+6) kW 20–70 °C yes 41 dB(A)
ERST30F-VM2EE 300 l tank 2050 × 595 × 680 mm 109 kg 2 kW 20–70 °C no 41 dB(A)
ERST30F-YM9EE 300 l tank 2050 × 595 × 680 mm 112 kg 9 (3+6) kW 20–70 °C no 41 dB(A)

Cooling: heating range 5–25 °C; max. tank temperature 70 °C; indoor unit ambient 0–35 °C (≤ 80 % RH). Source: ME Air to Water Catalogue 2026, p. 46–47.

Series model comparison

  • The power rating (e.g. 80 = 8 kW) corresponds to the nominal heating capacity at A2/W35.
  • All outdoor units have the same enclosure (1040 × 1050 × 480 mm); three-phase units are heavier and have a 16 A circuit breaker.
  • Acoustic power: 54 dB(A) for 80, 58 dB(A) for 100–140.
  • Three-phase indoor units (YM9E) have an auxiliary heater of 9 (3+6) kW, single-phase (VM2E) 2 kW.
  • The 300 l tank (ERST30) does not have a built-in expansion vessel and is taller (2050 mm); the 200 l tank is 1600 mm tall.

Comparison with other series

Mitsubishi Electric Ecodan from the Deltron range.

Series Refrigerant Capacity / power supply Max. heating range Heating up to Cooling Indoor unit
Eco Inverter (SUZ) R32 4–10 kW, 1 phase 60 °C −25 °C +10…+46 °C hydrobox or 170/200/300 L tank
Power Inverter (PUZ) R32 8–14 kW, 1 or 3 phases 68 °C −25 °C +10…+52 °C hydrobox or 200/300 L tank
Zubadan (PUZ-SHWM) R32 8–14 kW, 1 or 3 phases 70 °C −30 °C +10…+52 °C hydrobox or 200/300 L tank
Power Inverter R410A (PUHZ-SW120) R410A 12 kW, 1 phase 60 °C −20 °C −15…+46 °C hydrobox or 200 L tank
Zubadan R410A (PUHZ-SHW) R410A 8 / 11.2 / 23 kW, 3 phases 60 °C −28 °C (230: −25 °C) −15…+46 °C hydrobox
Ecodan Multi (PXZ) R32 1 air-to-air outdoor unit + air-to-water 55 °C −20 °C −10…+46 °C Ecodan hydrobox/tank (D)
Ecodan Multi Light R32 PXZ-5F85VG + tank 55 °C (65 °C with heater) −20 °C −10…+46 °C 200 L tank (stainless steel)

Values from the Deltron ME catalog (importer) (May 2026) and the ME Air to Water 2026 catalog. Heating up to = guaranteed operating heating range (outdoor temperature).

Which series is right for you

Eco Inverter
The most affordable entry into the Ecodan system: smaller and medium-sized buildings (4–10 kW), single-phase connection, flow up to 60 °C.
View the series →
Power Inverter
Higher flow (up to 68 °C) and higher capacities 8–14 kW, single-phase or three-phase – for radiator renovations and larger homes.
View the series →
Zubadan · this series
For the coldest locations: Flash Injection, guaranteed heating down to −30 °C and flow up to 70 °C.
Hydrobox or tank
The hydrobox (800 × 530 × 360 mm) is wall-mounted and leaves the choice of tank open; the tank version has an integrated 170/200/300 L stainless steel DHW tank.
View the hydrobox version →
Ecodan Multi / Multi Light
One outdoor unit for air-to-air air conditioning and Ecodan water heating or DHW – fewer outdoor units on the facade.
View the series →

Hydrobox or tank

Hydrobox Indoor unit with tank
Dimensions 800 × 530 × 360 mm (wall-mounted) 1400 / 1600 / 2050 × 595 × 680 mm (floor-standing)
DHW separate tank of your choice integrated 170 / 200 / 300 L tank
Advantage takes up little wall space, freedom of tank choice everything in one enclosure, factory assembled

What is included

Complete set: outdoor unit and indoor unit (with DHW tank) depending on the variant. The price is for the complete set. Wi-Fi interface, wireless controller, sensors and dual-zone kit are optional.

Variant designations

  • 8 kW / 1 phase / 200 L: indoor ERST20F-VM2E + outdoor PUZ-SHWM80VAA
  • 10 kW / 1 phase / 200 L: indoor ERST20F-VM2E + outdoor PUZ-SHWM100VAA
  • 12 kW / 1 phase / 200 L: indoor ERST20F-VM2E + outdoor PUZ-SHWM120VAA
  • 14 kW / 1 phase / 200 L: indoor ERST20F-VM2E + outdoor PUZ-SHWM140VAA
  • 8 kW / 1 phase / 300 L: indoor ERST30F-VM2EE + outdoor PUZ-SHWM80VAA
  • 10 kW / 1 phase / 300 L: indoor ERST30F-VM2EE + outdoor PUZ-SHWM100VAA
  • 12 kW / 1 phase / 300 L: indoor ERST30F-VM2EE + outdoor PUZ-SHWM120VAA
  • 14 kW / 1 phase / 300 L: indoor ERST30F-VM2EE + outdoor PUZ-SHWM140VAA
  • 8 kW / 3 phases / 200 L: indoor ERST20F-YM9E + outdoor PUZ-SHWM80YAA
  • 10 kW / 3 phases / 200 L: indoor ERST20F-YM9E + outdoor PUZ-SHWM100YAA
  • 12 kW / 3 phases / 200 L: indoor ERST20F-YM9E + outdoor PUZ-SHWM120YAA
  • 14 kW / 3 phases / 200 L: indoor ERST20F-YM9E + outdoor PUZ-SHWM140YAA
  • 8 kW / 3 phases / 300 L: indoor ERST30F-YM9EE + outdoor PUZ-SHWM80YAA
  • 10 kW / 3 phases / 300 L: indoor ERST30F-YM9EE + outdoor PUZ-SHWM100YAA
  • 12 kW / 3 phases / 300 L: indoor ERST30F-YM9EE + outdoor PUZ-SHWM120YAA
  • 14 kW / 3 phases / 300 L: indoor ERST30F-YM9EE + outdoor PUZ-SHWM140YAA
Technical data is taken from the Deltron catalog (importer) and the Mitsubishi Electric Air to Water 2026 catalog (translated by KlimaProdaja). Please check the availability of individual units before ordering.